As an , duct liner density is one of those topics that comes up for us on a regular basis. Every month, we receive a variety of questions around the impact of duct liner density pertaining to insulating performance, and reasonably so. In the past, duct liner density was thought to play an important role in the material鈥檚 insulating performance 鈥 both thermally and acoustically. Now, however, with modern manufacturing practices, advancements in material technology, and better testing procedures, we鈥檝e been able to identify which insulation characteristics truly impact performance, and which fall more into the red herring category.

In today鈥檚 world of improved manufacturing technologies, a material鈥檚 physical density is far less relevant to selecting a duct liner product because density has little correlation to thermal and acoustical performance. In fact, density as product selection criteria for duct liner was written out of the specification over 30 years ago!

In the 1970鈥檚, TIMA (the Thermal Insulation Manufacturers Association, which has since evolved into NAIMA 鈥 the North American Insulation Manufacturers Association) published a standard called 鈥淎HC-101-1975鈥 for fiberglass duct liner. This standard, addressed a number of critical characteristics that are still highly regarded today for duct liner performance, but it also was the genesis for standardizing liner density in specifications.

The thought process behind standardizing liner density evolved from the practice of using insulation density as the primary selection criteria for duct liner. At the time, industry professionals assumed incorrectly that all liners perform equally and that density was the key differentiator in insulating performance. The flaw in this logic is that all duct liners do not perform equally. In fact, design differences employed in manufacturing process technologies and airstream surface treatments are the key differentiators when it comes to insulation performance.  As such, density has little impact on actual duct liner performance. Generally, using outdated density specifications will often result in increased material costs without actually addressing the acoustical and thermal performance requirements of the application.

In 1986, insulation manufacturers and ASTM recognized that all duct liners aren鈥檛 the same. So they attempted to rectify this misconception by approving a new standard for duct liner selection criteria: ASTM C1071, the 鈥淪tandard Specification for Fibrous Glass Duct Lining Insulation (Thermal and Sound Absorbing Material)鈥. When this new standard for duct liner selection and specification was established, density was no longer listed as a required attribute.

The performance-based ASTM C1071 duct liner standard removes the guesswork from selecting a duct liner insulation system and provides the engineer, contractor, or building owner the freedom to focus on comprehensive duct liner performance rather than liner density. This means that they can write specifications based on acoustical performance, thermal performance, corrosive potential, fiber erosion resistance, surface burning characteristics, and other key duct liner performance characteristics.

As a consensus standard, the performance requirements in ASTM C1071 were established to be in accordance with ASTM C423, the 鈥淪tandard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method,鈥 and ASTM E795, the 鈥淪tandard Practices for Mounting Test Specimens During Sound Absorption Tests,鈥 using a Type "A" mounting for consistent acoustical results. It is important to point out that older publications may occasionally allow liner acoustical performance on a now obsolete F-25 model or alternate mounting option, which could elevate results. In order to ensure accurate product performance comparisons, engineers and specifiers should confirm that the mountings and test methods comply with ASTM C1071.

In addition to establishing acoustical and mounting requirements, ASTM C1071 also established minimum thermal performance requirements. The thermal conductivity is determined in accordance with ASTM C518, the 鈥淪tandard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus,鈥 at 75掳F mean temperature. R-Value and conductance are calculated from the thermal conductivity "k" factor.

So, this begs the question, if ASTM C1071 has been in effect since 1986, why do we still see density specified for duct liner? Great question! The simple truth is that master specs are rarely updated. Many times, challenging deadlines at engineering firms take priority over updating specifications to account for evolving software and advancements in technology.  In a time-crunch, specifiers will copy and paste specs from old projects without reviewing the details for accuracy. Over time, this pattern can cause the specifications fall behind the technology, standards, and needs of the industry.

This is why it鈥檚 critical to understand the reasons and history around why density is no longer relevant to duct liner performance. Updated duct liner specifications focus on providing the thermal and acoustical performance the project needs at a more cost-effective price point than outdated density-based specifications that require more glass/weight and, consequently, more cost.

That being said, there are occasional instances where the duct liner鈥檚 density is relevant, and these are largely focused around the duct hanging schedules. In this type of application, installers will want to know the duct liner density to ensure the hanging/securement method is sufficient to hold the weight of the system.

If you have questions about updating your specifications, please reach out to  and let us help you revise your specifications to make sure you are specifying the proper products for your project needs. Visit us on the web at .

.

Have a question for Johns Manville? Contact Johns Manville .

Johns Manville supports contractors with productivity-enhancing and performance-enhancing mechanical products, including duct, pipe, and building insulations.


Jul 30, 2024 Products & Services Update

Latest Articles


Why Should Your Business Have A Data Backup Strategy?

Mar 25, 2025 - Your business data is important. Losing it could be catastrophic. A data backup strategy can help ensure that you can recover critical business information after an incident.


Introducing Connectability for Drawings

Mar 25, 2025 - Procore鈥檚 Connectability for Drawings is now generally available, and it will redefine how companies collaborate.


Setting the Standard: Class 1 Safety Innovation

Mar 25, 2025 - The Lockformer Vulcan庐 Fiber Laser Cutting System, with its FDA Class 1 rating and patented shroud, ensures safety, precision, and efficiency.